(8)
Closed-loop models can attain linearity to 0.2 %.They require the P-177.10 option (strain gauge sensor) and are supplied with calibration data sheets.
Displacement to 80 µm
Pushing Forces to 2000 N
Pulling Forces to 50 N
Sub-msec Response
Sub-nm Resolution
Options : Vacuum, Low Temperature, Choice of End Pieces
(16)
Requires SGS sensor option, P-177.10. SGS versions can attain closed-loop linearity up to 0.2% and are shipped with performance reports. Sensor connection: LEMO FFA.0S.304; 1 m coaxial cable with PUR insulation.